qsfp dd connector pinout. 86: 10: $148. qsfp dd connector pinout

 
86: 10: $148qsfp dd connector pinout  It is backward compatible with 40G~200G QSFP type optical modules, including the prior 40G QSFP+, 100G QSFP28, and 200G QSFP56

These cabling components are the same as the recommended cabling components for 100G PSM4. 70: Buy. The QSFP-DD MSA will define a new pluggable form factor that supports 8 high speed electrical interfaces connecting to the host. Order today, ships today. 2. Backwards compatible with SFP. Responding to higher bandwidth demands, Active Electrical Cable (AEC) Solutions with QSFP-DD and OSFP Interconnects are a new category of pluggable connectivity designed for cost-effective , low-loss operation at 112G PAM-4 speeds and higher (port capacity between 100 and 800 Gbps) while increasing reach up to 5. QSFP-DD connector (Quad Small Form-factor Pluggable Double Density) MSA was preliminarily published on September 19, 2016. We sent everything off to the lab to get hooked up only to get a note back that the OSFP ends of the DACs did not fit into the OSFP ports of the. A QSFP connector cage could house 1 to 6 connectors. Available in 30 AWG wire size with data rate of 10 Gbps. Up to 40km: 400G QSFP-DD ER8 enables link lengths of up to 40km over OS2 SMF with duplex LC connectors. The dual QSFP-DD ports offer high-speed 4x40GbE or 2x200GbE connectivity. It is being developed by the QSFP-DD MSA as a key part of the industry’s effort to enable high-speed solutions. An SFP interface on networking hardware is a modular slot for a media-specific transceiver, such as for a fiber-optic cable or a copper cable. The QSFP-DD MSA will define a new pluggable form factor that supports 8 high speed electrical interfaces connecting to the host. Based on the design of QSFP, the form factor of QSFP-DD is identical to the previous QSFP+ and QSFP28. 8mm pitch SMT connector, and a press-fit cage. The SR8 module uses MPO-16 connectors or MPO-24 connectors to connect 8 pairs of fibers. 25G 2. Backwards compatible with SFP. This specification supersedes and extends INF-8438 QSFP (Quad SFP) 4 Gb/s 4X Transceiver and SFF-8436 QSFP+ 10 Gb/s 4X Pluggable Transceiver by supportingCompact connectors save space but tend to generate more heat, requiring time and money to be spent on cooling systems. The MSA had defined: - QSFP-DD Module form factor. 8 mm pitch connector built for use in high-speed serial. Yet it doubles the number of electrical interface lanes to 8 against 4 and provides the highest bandwidth in the QSFP cage system moduThe current web page context is a data sheet for Keysight AresONE 800GE QSFP — DD800 4/8-Port Test Systems, which are test solutions for PAM4 signaling-based Ethernet speeds of 1x800GE, 2x400GE, 4x200GE, and 8x100GE. 2 ResetL 18 5. The. Cage/Connector System QSFP-DD-to-4-SFP-DD Interconnect Cable Assembly Efficiently supports 4 port breakouts (2 lanes per port) in SFP-DD-to-QSFP-DD Cable Assemblies Complements QSFP-DD System capabilities. 5mm 16mm NET 13. The Double-Density module and connector design increases the number of high-speed data channels from four to eight for an aggregate bandwidth of 400Gb/s (8x50Gb/s). QSFP-DD: 76 Position: QSFP-DD: 76. 8 mm pitch connector built for use in high-speed serial applications. Nov 1,. Cisco Nexus 3000 Series Switches PanMPO to PanMPO multimode QSFP-DD optics and cabling productsmodule to outer environment. 0 specification. The differential lanes in orange can only be routed on any signal. Learn More about TE Connectivity te qsfp dd connectors assemblies . 3. Optech Technology Co. This feature grants QSFP-DD flexibility to fit the legacy. electrical model (S-parameter) of a QSFP-DD 1x1 surface mount connector for 16 differential pairs. the SFF Committee objectives were broadened to encompass other areas which needed similar attention, such as pinouts for interface applications, and form factor issues on larger disk. 7k–10kohmsonhostboardtoavoltagebetween3. QSFP-DD is developed by QSFP-DD MSA to address the high-speed and high-density networking applications. QSFP56 denotes 4 x 50 to 56Gb/s in a. 032 in] Centerline, Printed Circuit Board, Data Rate (Max) 112 Gb/s, High Speed. Provides excellent. 3 Mating Cables Below is a list of possible mating cables for the QSFP-DD receptacle/cage: Figure 6 shows the fiber breakout jumper pinout diagram for SMF or MMF applications using MFO connectors. The QSFP-DD MSA will define a new pluggable form factor that supports 8 high speed electrical interfaces connecting to the host. 400G PMDs Being Introduced. 0 updating QSFP-DD, introducing both QSFP-DD800 and QSFP112. 35mm, 89. Although QSFP-DD is a new connector/cage, it provides backwards compatibility with existing QSFP modules without the need for an adapter. It primarily enabled high-bandwidth optical links over 12-fiber parallel fiber terminated with MPO connectors. 2 Connectors The QSFP DD connectors on the FMC-PLUS-QSFP-DD offers the user a wide selection of interconnect schemes that break out the multi-gigabit transceivers on the FPGA. QDD ZR Plus overview The QSFP-DD ZR Plus variant complies with OpenZR+ MSA, allowing to cope for distances going from regional to long haul with multiple amplification sites between the end point. 2 Low Speed Signal Timing 20 5. 4Tbps of test traffic bandwidth and measurement. Example PECFF Quad-port 400GbE QSFP-DD NIC Using 64 Differential Signals 12 Figure 5-1. - 2-by-1 cage and connector form factor. QSFP-DD MSA announces HW Spec 6. 4 ModPrsL 19 5. About Us. Cisco currently offers passive This topic set provides installation, administration, remote administration, service, and command reference information for the Sun Datacenter InfiniBand Switch 36. 2 Connectors The QSFP DD connectors on the FMC-PLUS-QSFP-DD offers the user a wide selection of interconnect schemes that break out the multi-gigabit transceivers on the FPGA. 8mm and 13. PCB space, speed, channel and port density requirements. 0 Electrical ComparisonThe early 400G technology development is avoiding the "intermediate" form factors (i. QSFP-DD and QSFP Cage Assembly, Heat Sink, and Light Pipe All numerical values are in metric units [with U. Assembly Configuration. This means that equipment designed with QSFP-DD. Case temperature range 0°C to 70°C. a single height 1×1 surface mount cage and connector and a press fit 2×1 cage with integrated connector, thermal, pinout and. Wiring Ducts & Accessories; All Product Categories; Shop LADD Products;. Each port supports up to 400Gb/s in aggregate over an 8 x 50Gb/s electrical interface. Table 4 shows a similar comparison. loss interconnection between the ASIC site and the external QSFP DD IO port by overpassing the PCB. Rev 3. Figure 2. SN connectors offer a simpler and more efficient fiber infrastructure, and at the same time increased reliability. Lower power mode is added to allow up to 2W (Table 11-8). Eoptolink - market leader in high speed optical transceivers: 800G QSFP-DD800 & OSFP, 400G QSFP56-DD, QSFP112, OSFP, 200G QSFP56 and QSFP-DD, 100G single lambda QSFP28 and SFP56, QSFP28 BIDI LR4 ER4 ZR4 DWDM & CWDM, Coherent transceivers. Keywords: Cable Assembly; Cable Assemblies; QSFP Connectors; QSFP Connector Created Date the density of SFP+ interconnects. For Data Center Connections using 100G SR4 and 400G SR8 connecting MPO cable must be FEMALE due to QSFP28 and QSFP-DD modules having a built-in male connector/socket with guide pins. The QSFP-DD Specification defines a new pluggable form factor that supports 8 high speed electrical interfaces connecting to the host. Notice in the below QSFP 40G SR4 transceiver that the connector is not LC but a MPO/MTP12 receptacle. QSFP-DD doubles the density of QSFP and eight differential pairs capable of 50 Gbps each to achieve 400GbE while allowing existing QSFP modules to be plugged into the same cage. This will include a mechanical module, a 2x1. The double density feature is an. 8mm centerlines. The 100G QSFP28 PSM4 is a high-speed, hot-pluggable and low-power-dissipation optical transceiver with a built-in digital diagnostics function. Description. QSFP1-DD-EMI-HSK-S3 – Position QSFP-DD (Double Density) Cage Connector Press-Fit Through Hole, Right Angle from Adam Tech. 3. QSFP-DD, or QSFP56-DD, stands for Quad Small Form Factor Pluggable Double Density. Amphenol Communications Solutions' QSFP DD interconnect system is comprised of a 76-position, 0. Figure2: MPO-16 connector and MPO-24 connector. On May 24, 2021, the latest QSFP-DD800 was released by QSFP-DD MSA to run at up to 800G performance over 8 lanes of 100 Gb/s. Optical transceivers available in common form factors: QSFP-DD, OSFP, QSFP28, QSFP+, SFP+, XFP, SFP. QSFP-DD extends the use and usability of the QSFP family of modules to support higher speeds of 400G, 800G and now 1600G. 6. The SFP-DD form factor uses 2-lane pluggable modules, is backward compatible with SFP+ and offers improved host to module management communication based on a Two-Wire-Interface (TWI). 25 A current per pin. Two product variants are available: 1. At the very least that allows vendors the potential to upgrade existing 100G class products to 400G without front panel re-designs. 3. Table 1 lists each of the pins function. TE Connectivity (TE) Need Help? +1 800 522 6752 or Live Chat. The OSFP connector can deliver 33 W of power across its four power pins while the QSFP-DD connector can. The QSFP-DD will be able to support both optical and copper interfaces, but those physical layer. Compared to OSFP, QSFP-DD is based on the QSFP cage, delivering a max data rate of 200G, 400G, or 800G while with backward compatibility with the QSFP connector (QSFP+/QSFP28/QSFP56). Series: 204058 > Category: I/O Connectors; Overview: QSFP-DD Interconnect System and Cable Assemblies > Add to My Parts > Email this page > Request Samples > Something Missing On This Page? > Buy. SFP-DD revision 4. A. SFP-DD Module and Cage/Connector System delivers a 2-lane electrical interface, complementing QSFP-DD top-of-the-rack interfaces, and addresses issues caused by underpopulated lanes in file server interconnects. Commonly referred to as QSFP-DD, a more precise name would be QSFP56-DD where the 56. That is, the existing QSFP+ and QSFP28 transceivers can be inserted into QSFP-DD slots without any adapters. 7,303,438; 7,448,897 and USRE43427 on the plug side (which would cover both. Customers can upgrade their box before upgrading the cables and the infrastructure will not be. 10 thickTE’s QSFP-DD products leverage proprietary zipper fin heatsink technology allowing them to work cost-effectively in 15-18W applications. The “Q” is for “quad” — a nod to the four-channel electrical interface, with each lane running at 25 Gbps for 100GbE. 2 QSFP-DD Module Mechanical Package Dimensions 20 27 5. QSFP+. Series. QSFP-DD-400GBase-DR4 1310nmn,. 5m), plans for as small as 32AWGDescription Features Downloads PCIe x16 Gen 5 host interface board with PCIe dual QSFP-DD cable connectors that can be configured as x16 or two x8 cable ports. Customers can upgrade their box in advance of new cables, and their infrastructure won’t be idle while. Description. 76µm Gold (Au) Plated The CN176S-060-0002 60-pin OSFP connector meets the 4. Get 2318579-1 QSFP-DD specs, pricing, inventory availability, and more from TE Connectivity. The QSFP-DD will be able to support both optical and copper interfaces, but those physical. §Compatible with existing 100G QSFP based connector ports (with heat sinks and / or light pipes) as well as 200G /Interoperable coherent 400G/300G/200G/100G optical interface. OSFP, QSFP-DD 2x200G, 2x100G OSFP, QSFP-DD, SFP-DD 4x100G, 4x200G, 2x50G OSFP, QSFP-DD, SFP-DD 4x100G, 4x200G, 2x50G CS (Corning. 0 for QSFP-DD, QSFP-DD800 and QSFP112. 25. Breakout capability The 2x400G QSFP-DD modules have the capability to interface to multiple 100G and 400G modules, providing higher port density for 100G and 400G interfaces. 2. Ergonomic push/pull tabs make the cable easy to install or remove with one hand. QSFP-DD DR4 has a key advantage in that it can interoperate with 100G single lambda optics. In terms of SFP vs SFP+ compatibility, SFP+ ports often accept SFP. 2340397-1 CAGE ASSY W/ HS SPRING 2X1 QSFP-DD 2340397-2 CAGE ASSY W/ HS SPRING 2X1 QSFP-DD 2340397-4 CAGE ASSY W/ HS SPRING 2X1 QSFP-DD Heatsink* Type Heatsink Height Total Height** PCI 4. Labels: Labels: Cisco Champions; 0. Connector QDD-400G-SR8-S 400G QSFP-DD Transceiver, MPO-16 APC MMF, 100m OM4 MMF, Can be used for 2X 200G-SR4 and 8x 50G-SR breakout 12 MPO-16 MMF. 2340397-1 CAGE ASSY W/ HS SPRING 2X1 QSFP-DD 2340397-2 CAGE ASSY W/ HS SPRING 2X1 QSFP-DD 2340397-4 CAGE ASSY W/ HS SPRING 2X1 QSFP-DD Heatsink* Type Heatsink Height Total Height** PCI 4. Each NCS 1004 chassis provide four line card slots, and the Cisco NCS 1004 High. 5mm 16mm NET 13. Rev 1. As signal integrity and thermal performance remain imperative, the transceiver pads have been optimized to improve signal integrity for 100 Gbps. S. Commercial version transceivers are generally applied. 2mm 13. This will include a mechanical module, a 2x1 Cage with connector, thermal, pinout and management specifications. Examples of 100G SR4 on the left and 200G/400G SR8 on the right can be seen below: They use the same form factor, and the pinouts of SFP28 and SFP+ connectors are mating compatible. Non-Stocked. Image Gallery |. Also, QSFP-DD is backward compatible with the current QSFP form factor types, including 40G QSFP+, 100G QSFP28, and 200G QSFP56. Download Wiring Pigtail/Terminal Kits Identification. 5 meters, 3 meters. QSFP-DD refers to a double-density version of the QSFP transceiver supporting 200 GbE and 400 GbE Ethernet. 2031431254 – Position QSFP-DD (Double Density) Cage with Heat Sink Connector Press-Fit Through Hole, Right Angle from Molex. More optical connector configurations are added (Section 10. 2mm 13. The group has also announced the. Target Markets & Applications. TE offers a broad QSFP-DD portfolio which includes 1x1 through 1x6 cages and surface mount (SMT) connectors on a 0. 56G QSFP-DD 1x1 SMT connector: UE36-A10X5-X000T (X represents various options) QSFP-DD 1x1 cage assembly with heat sink and light pipe options: UE36-C16XXX-XXXXX (X represents various options) QSFP-DD 1x2 cage assembly with heat sink and light pipe options: UE36-C26XXX-XXXXX (X represents various options) Small Form-factor Pluggable ( SFP) is a compact, hot-pluggable network interface module format used for both telecommunication and data communications applications. The QSFP-DD specification and other hardware features include: A dual port integrated connector in a 2×1 stacked cage. , Ltd. It has the same pinout as the QSFP connector. Cisco currently offers passive copper cables in lengths of x=0. This will include a mechanical module, a 2x1 Cage with connector, thermal, pinout and management specifications. For the QDD-400G-SR8, the transceiver utilizes the MPO-16 connector for breakout to 2x QSFP-100G-SR4-S modules as shown in the following diagram with breakout to 8x SFP. The most commonly used 400G OSFP transceiver type is the OSFP SR8, which has a reach of 100m and uses an MPO-16 connector. 3. Handling Guidelines for QSFP -DD, QSFP, SFP Transceiver. You must ensure that you have a proper GND reference plane for signal routing. 7mm SAN 6. Some QSFP-DD modules have the capability to interface to multiple 100G modules when. 56G AND 112G DIRECT HIGH SPEED CONNECTION FROM CHIP SITE TO IO PORT QSFP DD OverPass™ products remove high speed signaling from the PCB and create an eight channel direct lower loss interconnection between the ASIC site and the external QSFP DD IO port by overpassing the PCB. QSFP28 Layout Design at the Connector with One Layer GND Cutout Below the Connector Pads (W (mil) x L (mil)) The performance results here are achieved by using a GND cutout at 50 mil x 65 mil, 67 mil x 75 mil, and the recommended 100 mil x 110 mil. APPLICABLE PART NUMBER 2147334000 MODEL TYPE: S-Parameters MODEL FORMAT: Touchstone (*sNp) MODEL. *Trunks available in fiber counts of 8 fiber to 288 fiber or higher. It allows a total of 400 Gbit/s via eight lanes. 2340397-1 CAGE ASSY W/ HS SPRING 2X1 QSFP-DD 2340397-2 CAGE ASSY W/ HS SPRING 2X1 QSFP-DD 2340397-4 CAGE ASSY W/ HS SPRING 2X1 QSFP-DD Heatsink* Type Heatsink Height Total Height** PCI 4. A1 EC No: 642848 DATE: of 62 20200805 DOCUMENT NUMBER: CREATED / REVISED BY: CHECKED BY: APPROVED BY: PS-204058-0004 Reid Walker J. The group also announces the release of an updated Common Management Interface Specification (CMIS) revision 5. 2 400G-SR8 400G-DR4 10km 2km 2km 100m 100m 500m. Installing the QSFP -DD Transceiver Module (Optical Transceiver Equipped with. The connector hardware offers a unique keying feature as opposed to the centered keying feature on the traditional MPO hardware. The tables in this topic describe the connector pinout information for the RJ-45, QSFP+, QSFP28, SFP+, and SFP ports. Mellanox Technologies 350 Oakmead Parkway Suite 100 Sunnyvale, CA 94085 U. Details. Using QSFP-DD breakout cables expands the connectivity to. 25G 6G:. The cage and connector design provides backwards. Each port supports up to 400Gb/s in aggregate over an 8 x 50Gb/s electrical interface. QSFP-40G-SR4= Cisco 40GBASE-SR4 QSFP+ transceiver module for MMF, multi-fiber MPO connector . SFP-DD Module and Cage/Connector System delivers a 2-lane electrical interface, complementing QSFP-DD top-of-the-rack interfaces, and addresses issues caused by underpopulated lanes in file server interconnects. 18. Singlemode DR4 modules are available for 500m, 2km and 10km reach with MPO or. High-Speed Pluggable Connectors. 3 Mating Cables Below is a list of possible mating cables for the QSFP-DD. QDD800-PCxx cables 800G OSFP/QSFP-DD PageThe new specification maintains the form factor’s eight electrical lanes with each lane operating at the new higher 200 Gbps rate to provide an aggregate module bandwidth capacity of 1. The connector features a paddle card entry slot that accepts 1. PECFF 12V PCIe Pinout for 2-64 Differential Pairs Configurations 21. QSFP DD ZR Application. The QSFP BiDi monitor is used only in the monitoring path of a link containing a passive optical tap splitter. . The OSFP interconnect system is a slightly larger connector than its QSFP-DD counterpart. Industrial Automation. 6V. The QSFP-DD will be able to support both optical and copper interfaces, but those physical layer. The following Juniper Networks USB flash drives have been tested and are officially supported for the USB port in the QFX Series: RE-USB-1G-S—1-gigabyte (GB) USB flash drive (except QFX3100 Director device) RE-USB-2G-S—2-GB USB flash drive (except QFX3100 Director device) RE-USB-4G-S—4-GB. It increases the data rate of each of the eight lanes to 100 Gbps. 00mm Fiber (Core/Cladding) 50/125µm OM3 Net Weight 46. 2. With four channels of data in one pluggable, the system interface is capable of transferring data up to 16Gb/s per Channel, and replacing up to 4 standard SFP+ receptacles. Wiring Devices. Unless stated explicitly, these transceivers also support four independent lanes of 100Gbps rates, which are determined by either wavelength for LC connector types or fiber for MPO connector. The tables in this topic describe the connector pinout information for the RJ-45, QSFP+, QSFP28, SFP+, and SFP ports. Pricing and Availability on millions of electronic components from Digi-Key Electronics. Get a. Aruba uses the abbreviation of Q-DD interchangeably for QSFP-DD. April 25, 2018 FOWIKI. The lane mapping for the 16-lane and 8-lane configurations is shown below. 1 ModSelL 18 5. Backwards compatible with SFP. 1 PRODUCT NAME AND SERIES NUMBER(S) Product Name: QSFP-DD 800 112G, SMT CONNECTOR Connector Series: 216252(2x1), 214733(1X1) Plug & Cable Series: 212675 Cage Series: 214650(2X1 GLUE VERSION), TE Connectivity’s (TE) QSFP-DD (quad small form-factor pluggable double density) doubles the density of QSFP interconnects with an eight-lane electrical interface capable of 28 Gbps NRZ or 56 Gbps PAM-4 to achieve 200 or 400 Gbps aggregate per port. 76µm Gold (Au) Plated SFP-DD Module Sytem. copper cable integrates a 400G Ethernet-optimized (400 GbE) 38-position "board as connector" design. pdf EnglishWhat is QSFP-DD Modules. These products are designed for both 28G NRZ and 56G PAM-4 protocols, with a roadmap to 112G PAM-4 for future system. QSFP (Quad Small Form Factor Pluggable) – A bidirectional transceiver or cable with 4 lanes in each direction. connector from EMI Reference base part number 2170709 on page 7 EMI Enhanced Thermally Enhanced Lower Port Cooling Internal riding heatsink in the seperator plate area provides enhanced cooling to the lower ports and a 12-15oC improvement over standard stacked zQSFP+ cages. Some assemblies have support for QSFP28 or QSFP-DD transceiver modules. The QSFP-DD, which is a pluggable transceiver, with an additional row of contacts to provide for an eight lane electrical interface, is introduced while maintaining the footprint to allow backward compatibility with the standard QSFP form factor. 12 :: Specification for OSFP Octal Small Form Factor Pluggable Module. Typical Connector DOM: SIZE: POWER CONSUMPTION : APPLICATION: PRICE: SFP: SFP MSA: 155M 622M 1. Connector Pin Assignment Figure 2 shows the arrangement of the output pins from the QSFP receptacle on the QSFP-BB. 3 Low Speed Signal Descriptions 18 5. : 1. Dimensions. 5m), plans for as small as 32AWGThe QSFP-DD OLS can extend the reach of a 400G Bright QSFP-DD ZR/ZR+ link from 80 to 130 km or longer depending on fiber specification, the channel count, and the line rate of the signal. 2 ResetL 18 5. It is being developed by the QSFP-DD MSA as a key part of the industry’s effort to enable high-speed solutions. 2 QSFP Example Circuits 16 5. Get 2343246-1 QSFP-DD specs, pricing, inventory availability, and more from TE Connectivity. 8 Color Coding and Labeling of QSFP-DD Modules 35 QSFP-DD Interconnect System’s 8-lane electrical interface transmits up to 28 Gbps NRZ or 56 Gbps PAM-4, up to 200 or 400 Gbps aggregate, with the same footprint as QSFP Interconnects, making them backward compatible FEATURES AND ADVANTAGES FEATURES AND ADVANTAGES Temp-Flex cable technology Boosts electrical performance. The new QSFP-DD800 1. RF Cable Assemblies. It has the same pinout as the QSFP connector. 5mm 23mm TE’s thermal engineering team will work directly with you to design and optimize. This specification covers the Performance Requirements of QSFP-DD 800 112G, SMT Series Connector. The electrical pinout of the QSFP-DD module is shown in Figure 2 below. The Cisco NCS 1004 High-Density QSFP-DD Transponder (Figure 1) is a single-slot line card capable of supporting 16xQSFP-DD ports, -8xQSFP-DD client ports with 400GE, 100GE and OTU4 interfaces (available in roadmap) and 8xQSFP-DD trunk ports. The QSFP-DD will be able to support both optical and copper interfaces, but those physical layer. 2. The 400G DR4 QSFP-DD optical transceiver is the latest solution for high-speed networks, making it an essential tool for businesses that rely on large amounts of data processing. QSFP-DD is a new module and cage/connector system similar to current QSFP, but with an additional row of contacts providing for an eight lane electrical interface. 4mm/min. QSFP+. 7 Host PCB Layout 31 32 5. This will include a mechanical module, a 2x1 Cage with connector, thermal, pinout and management specifications. AIoT Solutions - mPACT2WO;. 1 Low Speed Signaling 20 5. The cable usually cannot be twisted for proper. QSFP112 is the module and cage/connector system based on current QSFP, targeting to support the 112Gb/s per lane speed in a 4x lane QSFP system and to enable the QSFP 400G interconnect ecosystem. 0 and thermal design whitepaper. 5m), plans for as small as 32AWGAs the evolution of QSFP (quad small form-factor pluggable), the QSFP+ module is a compact, hot-pluggable transceiver used for 40Gbps speed. All Vendor Specific, Reserved and No Connect pins may be terminated with 50 ohms to. 6 Tbps. 4. USB Type A-to-USB 5-Pin Mini-Type B Cable. AdrenaLINE Slingshot . EMI plugs are offered for empty ports. 400G, QSFP-DD to QSFP-DD, Passive Copper Cable, 0. In other words, a total of 256 differential pairs with 32 ports delivers double-lane density within the same form factor. It has the same pinout as the QSFP connector. 3V power supply is required to power up this product. Loop optical transmit ports to receive ports: Allows loopback testing of modules, cables during burn in and field troubleshooting. 6). 5mm 23mm TE’s thermal engineering team will work directly with you to design and optimize. Get 2372133-2 QSFP-DD specs, pricing, inventory availability, and more from TE Connectivity. Network Port, QSFP+ Port, SFP Port, and SFP+ Port Connector Pinout Information for EX4300 Switches. CVR-QSFP-SFP10G 40G QSFP+ to 10G SFP+ Adapter Converter Module Notes: 1. 5mm 23mm TE’s thermal engineering team will work directly with you to design and optimize. the OSFP1600 specification will also define cabled-connector footprints in addition to the traditional surface mount (SMT) connector. The signaling operates in the C-band. QSFP-DD 400G ports of switches/routers within racks and across adjacent racks. Backwards compatible with QSFP. 2mm 13. The SFP-DD will be able to support both optical and copper interfaces, but those physical layer specifications. 400G-LR8 400G-FR8 400G-2FR4 400G-SR4. The PMD in IEEE802. 3. QSFP-DD Double Density Pinout. Based on the design of QSFP, the form factor of QSFP-DD is identical to the previous QSFP+ and QSFP28. 26 5. Description. MTP/MPO-16 connectors. A. MDC connectors, cable assemblies, patch panels and cassettes are intended for dense connector environments, feature proven 1. QSFP to QSFP I/O Cable Assembly: 30 AWG. The QSFP-DD modules can support 400Gbps while QSFP+/QSFP28/QSFP56 can only reach 40Gbps/100Gbps/200Gbps respectively. It primarily enables high-bandwidth 100G optical links over 12-fiber parallel fiber terminated with MPO multifiber connectors. 2057-QSFP1-DD-EMI-HSK-S3. QSFP-DD, or QSFP56-DD, stands for Quad Small Form Factor Pluggable Double Density. Available in a variety of optical interfaces: Options for BiDi, Duplex SMF, Parallel SMF, MMF. The QSFP-DD module contains a PCB with a 76-contact card-edge electrical interface to external host-side logic. 5m), plans for as small as 32AWGThere is more addition to QSFP family form factors, such as 200G QSFP56 and 400G QSFP56-DD. The QSFP-DD specification provides both single-height and stacked configurations of the cage/connector system, supporting QSFP modules and QSFP-DD modules through. The term. Unlike the QSFP28 SR4 module, the QSFP 100G PSM4 transmits on a single-mode fiber with a. SFP+ and SFP28 have the same form factor, and compatible pinouts. MTP/MPO QSFP+ connector interface: Meets QSFP+ SFF-8665 interface specification. Target Markets & Applications. I have this problem too. QSFP and QSFP+: QSFP carries 4 x 1 Gb/s channels. Amphenol's ExtremePort™ QSFP DD 112G interconnect system is comprised of a 76 position, 0. The QSFP-DD is identical dimensionally with the QSFP and its edge connector is designed in such a way as to allow QSFPs to be supported in QSFP-DD slots without and adaptor. The new form factor specification is a follow on to the QSFP-DD specification. 7mm SAN 6. Amphenol Communications Solutions' QSFP DD interconnect system is comprised of a 76-position, 0. 0mm. 652 single-mode fiber with duplex LC connectors. A. 6 1. 6 Tbps host port maintains backwards compatibility with the entire family of QSFP and QSFP-DD modules and cables. The intended use for the DR1 is to interface with the 400G DR4. 5, 1, 2, 2. A. These modules have different variants, some of which provide multiple physical ports out of a single module (breakout modules). 1 ModSelL 18 5. 5mm 16mm NET 13. 1 Electrical Connector 14 5. The QSFP-DD can support. 0m without optical cables. 8mm pitch connector built for use in high-speed serial applications. 8 mm Centerline, Printed Circuit Board, Data Rate (Max) 56 Gb/s, Signal, -67 – 185 °F [-55 –. QSFP-DD to QSFP-DD Across DC With Trunk 400G-DR4 to 400G-DR4 Note: NAFTA uses plenum/riser cable and EMEA/APJ uses LSZH™ cable. 4 modules can be plugged only into Vita57. An optical fiber cable with an MTP/MPO -12 connector can be plugged into the QSFP-DD DR4+ module receptacle. The Intel® Silicon Photonics 400G DR4+ (Data center Reach 4-lane with extended reach) QSFP-DD Optical Transceiver is a small form-factor, high speed, and low power consumption product, targeted for use in optical interconnects for data communications applications. The QSFP-DD will be able to support both optical and copper interfaces, but those physical layer. 3. 400G OSFP transceiver provides a good solution for 400Gbps optical deployments in data centers and broadband access connectivity. Loop optical transmit ports to receive ports: Allows loopback testing of modules, cables during burn in and field troubleshooting. These expand on the QSFP form factor, the industry’s leading multi-lane pluggable form factor used across Ethernet, Fibre Channel and InfiniBand for 40 Gbps and 100 Gbps network. 2-BD. The transmit and receive of the optical lanes of the MPO-12 interface occupy the positions depicted in the following figure when looking into the module. 5mm 16mm NET 13. A mated connector + CTV PCB model was simulated up to 60GHz using ANSYS HFSS in the Frequency domain. DATA AND DEVICES /// QSFP-DD CONNECTORS & CABLE ASSEMBLIES PAGE 5 Cable Assemblies • QSFP-DD cable assemblies are similar to QSFP28 4 channel (8 pair), but use double the channels to 8 (16 pair) by using a 2nd row of contact/pad locations on the front of the PCB • 16 pair 28AWG cable maximum fit (2. Because bigger connectors help with airflow and colling, OSFP connectors generate less heat, doing their part to mitigate thermal issues.